Download a Printable Version Here (Adobe Acrobat Format) Distillation Pilot Plant Design,
Operating Parameters and Scale-up Considerations An important feature of the stainless steel tower is that it is provided with observation windows designed to withstand a pressure of 4236 kPa (600 psig) at 287°C. There are two pairs of windows in the vicinity of the reflux distributors and two pairs at the center feed location. One window of each pair is 100 mm in diameter used for illumination and the other window, which is perpendicular to the first, is 150 mm in diameter and is used for observation. The carbon steel distillation tower has three observation windows (150 mm diameter) in the vicinity of the reflux distributor. These observation windows permits the operator to observe the performance of the distributor, to look for any entrainment of liquid in the vapor and the onset of flooding. These windows have proved to be extremely valuable tools to characterize the distillation performance of the tower packings and distributors that have been tested over the years. In the design of both pilot plants particular attention has been paid to minimize the hold-up of liquid in the overhead condensate circuit, viz., condenser, condensate line, condensate tank and reflux line. Both pilot plants use vertical condensers with the vapor condensing in vertical tubes thus minimizing the hold-up of the overhead product. The reboilers of both pilot plants are just large enough to hold sufficient charge of liquid such that the increasing hold-up of liquid in the packing resulting from increasing boil-up does not drastically deplete the reboiler liquid of its light component. The carbon steel reboiler can hold up to 0.38 cubic meters (100 gallons) of liquid and the stainless steel reboiler can hold up to 0.57 cubic meters (150 gallons) of liquid. The members of FRI and SRP have access to the test data generated in the respective test columns. FRI has the capability to run high vacuum to high-pressure systems and the SRP can run systems from high vacuum to 507 kPa (60 psig), but neither FRI nor SRP has the capability to run corrosive systems. FRI has 1213 mm (47.75 in.) and 2438 mm (8 ft.) I.D. column sections whereas the SRP tower has an I.D. of 429 mm (16.875 in.). As far as the authors are aware of, NCPPCs stainless steel distillation pilot plant is the only one that is capable of testing all commercial size packings from high vacuum to high pressure in both non-corrosive and corrosive systems. We have tested all sixes of NCPPC random packings in one of the two pilot distillation units. The tower diameter-to-packing size ratio ranged from 5.5 to 26. This list includes all sizes of Intalox Metal Tower packings (IMTP packing), Pall rings, Hy-Pak packing and several other random packings. Furthermore, all sizes of NCPPCs Intalox structured packings viz.; 1T, 2T, 3T, 4T and 5T, were also tested in these pilot distillation columns. |
ChE Plus Subscriber - Click Here for a Printable Version
Send this Page to a Friend