Power Recovery Turboexpanders - Shaft Power Available




Power Recovery Turboexpanders - Shaft Power Available Dear All,

Commercial applications of high temperature power recovery turboexpanders use the expander to drive an air compressor which charges the process unit that produces the high temperature gas that expands to atmosphere across the turboexpander. The compressor/expander unit, together with its process unit, is therefore very similar to a special purpose combustion gas turbine engine cycle, with the process unit as the "combustion chamber."

Power recovery from Catalytic Cracker flue gases is one of the most important applications using turboexpanders in the petroleum refining field. FCCU Hot Gas Expanders are commercially available in speeds from 3600 to 7500 rpm, gas inlet conditions to 4.8 bara (70 psia) and 760°C (1400 deg F). Exhaust pressure is typically 1.24 bara (18 psia), mass flows range from 200,000-640,000 kg/h (440,000-1,410,000 Ib/hr). Power recovered ranges from 2600-37,300 kW (3500-50,000 hp). Units are typically 1 or 2 stages.

Today's blog entry provides the calculation for shaft power available from a power recovery turboexpander:

Attached Image


Attached Image

where:
ηi = Isentropic Efficiency. Use 85% for "as new" efficiency until specific vendor estimates are obtained. Assume an average isentropic efficiency 5% lower than the "as new" condition for economic studies that allow for erosion during a three year run.
ηm = Use 99%, allowing for bearing losses, and assuming no gear unit.
M = molecular weight of inlet gas, kg / kg-mol (lb / lb-mol). Assume value as 30.2 till specific flue gas analysis is available.
R = gas constant 8.31447 (1545) kJ / kg-mol.K (ft-lbf / lb-mole.⁰R)

W = Mass flow rate, kg/s, (lb/min)
T1 = Inlet temperature, K (⁰R)
T2 = Exhaust temperature, K (⁰R)
k = specific heat ratio; use 1.3 unless the flue gas analysis gives a better value
P1 = gas pressure at expander inlet flange, kPaa (psia)
P2 = gas pressure at expander exhaust flange, kPaa (psia)
Z = avg compressibility factor ((Zin + Zout) / 2)

Expander Exhaust Temperature:

Attached Image

The expander exhaust temperature is used to calculate the remaining flue gas heat which is still available for recovery by other means.

That is all for today. Hope to have comments and observations from members.

Regards,
Ankur.




Thank you for this. Will this still be applicable if I was dealing with compressed air operated tool? The air is not high temperature but room temperature (70F) and expanding from 190 psi to atmospheric. 

Latest Visitors

  • Photo
    Falah
    Yesterday, 03:08 PM
  • Photo
    liliov
    Yesterday, 02:46 PM
  • Photo
    poojabathula369@gmail.com
    Yesterday, 01:18 PM
  • Photo
    kNdash
    Yesterday, 12:48 PM
  • Photo
    nitish Rai
    Yesterday, 06:18 AM
  • Photo
    hysyshunter
    Yesterday, 05:09 AM
  • Photo
    naufalovich
    Yesterday, 02:36 AM
  • Photo
    harisrikar
    23 Apr 2024 - 21:44
  • Photo
    AlfreRam
    23 Apr 2024 - 16:04