Heat Flux And Maximum Film Temperature For Fired Heaters




Heat Flux And Maximum Film Temperature For Fired Heaters Today I was going through some write-up related to fired heaters from old manuals of a world-class operations company and found some very good information related to "Heat Flux" and "Maximum Film Temperature" for fired heaters used in various services. Although process design engineers working for general engineering consulting firms could never think of designing a fired heater on their own, one of the most common activity related to fired heaters would be the preparation of a process data sheet for a fired heater by a process engineer. Data such as average and peak heat flux and maximum film temperature would be required to be filled in the datasheet for a fired heater.

Before going into the figures for heat flux and maximum film temperature it is important to understand what these terms mean in context to a fired heater.

In general heat flux is the main determinant for the tube area of a fired heater. It has the units kW / m2 in SI units and Btu / hr*ft2 in English units. It is the rate of heat transmission through the tubes into the process fluid. The area used in the specification of heat flux is usually the outside tube area in the radiant section. Heat flux can be classified as the average heat flux and the peak heat flux for a fired heater.

Average Heat Flux
The average flux is obtained by dividing the duty of the radiant section by the total exposed outside tube area. This approach is valid for "well-mixed" fireboxes where there is little variation of flue gas temperature throughout the box. (Steam reformer heaters in hydrogen, ammonia and methanol plants are an important exception).

If the flux is too high in the radiant section of an existing heater, the only way to decrease it is by reducing the firing rate.

Peak or Maximum Heat Flux
Suppose a bank of tubes, with a center-to-center spacing of two tube diameters, is placed one or two tube diameters away from a refractory wall and is uniformly fired from the opposite side of the wall then the side of the tube facing the flame will receive direct radiation and the opposite side will receive radiation reflected from the wall. The hottest point on the tube will be on the side facing the flame where the surface is at a right angle to the flux. This is the peak or maximum heat flux and it will be about 1.8 times the average value.

When the bank of tubes is placed in the center of the firebox and is fired uniformly from two sides, the ratio of peak to average flux will be 1.2. This illustrates the advantage of two-sided or double firing. Thus for a given peak flux, the average flux will be 50% greater than in the case of single or one-sided firing.

For most fired heater applications the peak flux values are in the range of 47 to 69 kW/m2 (15,000 to 22,000 Btu/hr*ft2) and average flux values are in the range of 25 to 47 kW/m2 (8,000 to 15,000 Btu/hr*ft2). Refer the attached table for average heat flux values.

Maximum Inside Film Temperature
Flux, either peak or average, is a useful parameter to fix when specifying a fired heater for design. Excessively high flux will cause tube overheating and even lead to damage of the heater refractory walls. But what is really of concern from the process view point is the maximum inside fluid film temperature. This is the maximum temperature that the fluid sees.

The maximum temperature difference across the inside film can be calculated as the peak flux (adjusted to the basis of the inside tube area) divided by the inside (convective) heat transfer coefficient. This difference when added to the maximum process bulk temperature provides the maximum film temperature. Recommended maximum film temperatures for some applications are provided in the attached table. Inside heat transfer coefficients range from a minimum of 0.11 kW/m2*K (20 Btu/ft2*h*degF) for gases up to approximately 5.7 kW/m2*K (1000 Btu/ft2*h*degF) for boiling water (steam generation).

Fouling
For heaters with with tubes known to be subject to inside fouling, the process engineer may specify a temperature allowance for fouling. This temperature difference is added to the maximum inside film temperature to get the inside tube metal temperature. It will affect the mechanical design of the tubes. Temperature allowances are in the range of 10 to 38 deg C (50 to 100 deg F). Refer the attached table.

Attached Image

So that is about it for heat flux and maximum film temperature for fired heaters. The table attached for recommended values is the recommendation of a particular company. These values may be different based on design and operating experience of another company and hence I advise the engineers to verify the figures for suitability to the fired heater design objectives of any other company for which they are providing the data.

Hoping to have some comments on this entry from the readers of my blog.

Regards,
Ankur.




Ankur,
I really appreciate that you take time and write these beneficial article for young engineer like us.

thank u for ur valuable info. kindly reply me back with the process design calculation for indirect water bath heater if possible. 

sir, how can i size the shell length and diameter of water bath indirect line heater

Thanks a lot sir for sharing this valuable info with us.

 

Could you please post How to calculate Heater Efficiency/duty and Burner efficiency as well.

 

Thanks in advance

Dear Sir,

Many thanks for the great information. If you have a basic procedure for the mechanical and process design of the fired heater for the crude distillation please upload it.

 

Thanks

Robert

Where do I find the  values of film coefficients for typical process heaters ?   I was trying to calculated the peak film temp for a Visbreaker furnace as per API 530.  It needs the heat tranfer coeff for both liquid & vapor phase at the bulk temp.    However, I am unable to get that.

 

If you can point me to any source, that will be wonderful

 

regards

 

Chakraborty

Where do I find the  values of film coefficients for typical process heaters ?   I was trying to calculated the peak film temp for a Visbreaker furnace as per API 530.  It needs the heat tranfer coeff for both liquid & vapor phase at the bulk temp.    However, I am unable to get that.

 

If you can point me to any source, that will be wonderful

 

regards

 

Chakraborty

Chakraborty,

 

Have a look at the link below:

 

http://www.ijetae.co...TAE_0313_09.pdf

 

Regards,

Ankur.

Hi Ankur, thanks for share your knowledge.

 

You know, where i can find information for calculate heat transfer coefficient in fired heater, specifically, convection section. 

 

Furnace type: box, with top vertical burners.

Application: Steam reforming (methanol plant)

Fuel: Natural Gas

 

Coils in convection section: Somes are finned, other not.

 

Mi intention, not are design.

 

Thanks for all.

Photo
FiredHeaterExpert
Aug 31 2021 07:01 PM

Thanks for this post Ankur.

 

I see the post was created a long time ago, but for the interest of any new visitors, I'd like to add the following information:

 

When designing a Fired Heater, once you have selected (or been provided with) an appropriate heat flux for your heater, you can then begin to deduce the sizing of your Radiant Section.

 

Let's assume you need to design a heater to absorb 10MW...

 

It reasonable to assume that 70% of your fired heater duty will occur in the radiant section, and so the radiant duty will be 7MW.

 

Dividing the 7MW by your specified flux will give you the total surface area you need in you Radiant section.

 

From the surface area, and assuming a reasonable tube size (6"NB), then you can deduce your overall tube length required.

 

With some fairly logical steps, you'll be able to arrive at a very good first approximation of a workable radiant section size.

 

A good description of this is laid out at:

https://www.heatersi...icle-2050_95345

 

 

Thanks again for your information.

Your table summary of the fluxes is particularly useful and generally inline with typical requirements I've seen for each heater type listed.

Latest Visitors

  • Photo
    daraj
    Today, 04:24 AM
  • Photo
    hilman01
    Today, 01:15 AM
  • Photo
    newtonslaw
    Yesterday, 02:58 PM
  • Photo
    Cramirez
    Yesterday, 09:21 AM
  • Photo
    Shashank JS
    Yesterday, 05:29 AM
  • Photo
    Platonicus
    Yesterday, 12:25 AM
  • Photo
    anirudhan86
    26 Mar 2024 - 23:08
  • Photo
    UrosBozovic
    26 Mar 2024 - 18:09
  • Photo
    yusifsam95
    26 Mar 2024 - 11:30