Tower Sizing and Pricing

          The program that I have posted on this page can be used to perform preliminay size and cost estimates for
distillation columns with internal trays.  It is in Microsoft Excel format (version 5.0 or greater) and runs as an Excel Add-In.   The program assumes cooling water (water entering at 300C and leaving no higher than 450C) is used in the condenser.  LPS (Low Pressure Steam) is assumed to be at 5 barg and 1600C, MPS (Medium Pressure Steam) at 10 barg and 1840C, and HPS (High Pressure Steam) at 41 barg and 2540C.  Here are some other details of the this EXCEL ADD-IN:

  • The condenser is priced as a Fixed Head Exchanger

  • The reboiler is priced as a Floating Head Exchanger

  • Minimal inputs are required for the column sizing and pricing

  • Returned values include the cost of the vessel, trays, reboiler, condenser, steam, cooling water, and a local Net Present Value (over 10 years at an interest rate of 10%) for the column operation.  This value can be used for optimization

  • Utility prices used are: LPS $3.17/GJ,  MPS $3.66/GJ, HPS $5.09/GJ, and CW $0.16/GJ

  • The equipment is prices using correlations developed by G. D. Ulrich in A Guide to Chemical Engineering Process Design and Economics, Wiley, New York 1984.  These correlations have also been reprinted in Analysis, Synthesis, and Design of Chemical Processes by Richard Turton, Richard Baile, Wallace Whiting, and Joseph Shaeiwitz (Prentice Hall, 1998).  These correlations are well developed and provide a good degree of accuracy for a preliminary design.

  • Length and diameter of column is also estimated

          If you have any other questions concerning this program or would like to report a bug, please let me know.  


addin1.gif (86695 bytes)

Download the Add-In
The registration code for the Add-In is 112874082778


ChE Plus Subscriber - Click Here for a Printable Version

Fill out your email address to
receive notification of site updates
and instantly receive five technical
questions and answers
!
Email Address:
First Name:
Last Name:

State:

Country:

Industry:

Position:

Signup Remove