Download Time Dependent Non-boiling Liquid Outflow Through a Hole from a Vertical Cylindrical Vessel

* * * * - 1 Votes
time drainage vertical tank



Screenshots

MS Excel spreadsheet for estimating the time for partial and complete draining of an atmospheric storage tank (vertical cylindrical) containing a non-boiling or sub-cooled liquid and also the liquid inventory left in the tank after a certain period of time. This is only applicable to vertical cylindrical tanks and not for horizontal or tanks with dished ends.



Disclaimer: All software provided "As-Is" with no warranty, expressed or implied, available. See our Terms of Use for more information.




Great Ankur SIr.

 

Thank you very much. This is a beneficial knowledge.

Photo
toabhishek@gmail.com
Apr 15 2014 02:10 PM

Hello Ankur

 

Thanks for sharing this information.

Hello Ankur

 

Thanks for sharing this information.

I have a question - How did you incorporate friction factor (f) in the calculation of mass flow relating to pressure difference.

In the excel file, I think you have used f = 1, what is the assumption behind this ?

 

I would be thankful if you can answer my questions

 

Best

 

Abhishek

Abhishek,

 

Have you read the "Theory & Equations" worksheet of the excel workbook. Equation 2.194 has no Friction factor term in determining the mass flow which ahs been used in the "Liquid Outflow Calcs" worksheet. Hope this answers your query.

 

Regards,

Ankur