Jump to content



Changes in Centrifugal Pump Calculator 1.1

Version 1.1
  • Row 47 the formula should be
  • = H42*H35/1000/10.2+H41-H45-H46
  • (Original formula had 10000 ie Row 47 = H42*H35/10000/10.2+H41-H45-H46)
  • Thanks to SenOil for drawing the attention.
Version 01
  • Row 47 the formula should be
  • = H42*H35/1000/10.2+H41-H45-H46
  • (Original formula had 10000 ie Row 47 = H42*H35/10000/10.2+H41-H45-H46)
(Previous Version)
No changes have been recorded in this version