Submitter
File Information
- Submitted: May 05 2011 08:12 PM
- Last Updated: May 05 2011 08:12 PM
- File Size: 347KB
- Views: 242273
- Downloads: 29,184
Download Process Engineering Calculations
32 Votes
83
Calculations in MS Excel include:
- Heating time using hot water (Non Isothermal Heating Medium)
- Heating time using steam (Isothermal Heating Medium)
- Cooling time using non isothermal cooling medium
- Heating time using external Heat exchanger & Non Isothermal Heating Medium
- Heating time using external Heat exchanger & Isothermal Heating Medium
- Cooling time using external Heat exchanger & Non Isothermal Cooling Medium
- Cooling time using external Heat exchanger & Isothermal Cooling Medium
- Calculate the Heat Transfer coefficient for reactors based on different agitator types & utility flow rate
- Calculate the addition time required based on heat of the reaction, Type of agitator, MOC & utility flow rate in a semi batch reactor
- Scale up of reactor from lab to plant scale
- Calculate the vacuum pump flow rate based on air leakage rate
- Power required for pumping
- Pump affinity law
- Pipe flow distribution
- Pressure drop across pipe lines
Disclaimer: All software provided "As-Is" with no warranty, expressed or implied, available. See our Terms of Use for more information.
great simple work
Its great work. Thanks for this useful post.
I have downloaded and it is excellent piece of information.
thanks a lot..
thanks a lot..
simply useful, thanks cher..
Very much useful, and timely, thanks guys,
it's simply amazing.thanxs.
I downloaded this tool and it is great simple one but the
Pipe flow distribution Module (#14)
gives error and could not depug, please advise
Pipe flow distribution Module (#14)
gives error and could not depug, please advise
Good Morning Dear,
If you are using Excel 2003 version, follow the below instruction
1. In tools menu, click add ins and select the solver add in radio button to activate the function.
2. In tools menu, click macro select the macro and go to edit option. Then select tools > Reference>solver add in radio button and save the file.
You try this. If not working send your mail address with your office version, i will send you the calculation file as there is no option to upload file in reply post.
Cheer's
MK_Chem
If you are using Excel 2003 version, follow the below instruction
1. In tools menu, click add ins and select the solver add in radio button to activate the function.
2. In tools menu, click macro select the macro and go to edit option. Then select tools > Reference>solver add in radio button and save the file.
You try this. If not working send your mail address with your office version, i will send you the calculation file as there is no option to upload file in reply post.
Cheer's
MK_Chem
Thanks for ur kind reply. I am using office 2007 and it works now
Able
Able
THANKS A LOT!
I'll post later again.
I'll post later again.
Random Files
- 326 Total Files
- 28 Total Categories
- 42 Total Authors
- 1,046,609 Total Downloads
- Multiphase Slug Length and Volume Calculator Latest File
- ankur2061 Latest Submitter
user(s) are online (in the past 15 minutes)
members, guests, anonymous users