steam ejector calculation

Semi-empirical equation for entrainment ratio based on curve fitting of design data obtained from reputed ejector manufacturers such as Schutte-Koerting, Croll-Reynolds and Graham. The curve fitting equation is fairly satisfactory for the entrainment ratio range between 0.2 & 1. The calculated entrainment ratio may then be used to calculate the mass flow rate of motive steam or entrained vapor given either one of them.
Disclaimer: All software provided "As-Is" with no warranty, expressed or implied, available. See our Terms of Use for more information.
Random Files
- 326 Total Files
- 28 Total Categories
- 42 Total Authors
- 1,058,250 Total Downloads
- Multiphase Slug Length and Volume Calculator Latest File
- ankur2061 Latest Submitter
user(s) are online (in the past 15 minutes)
members, guests, anonymous users
The curve fitting equation is fairly satisfactory for the entrainment ratio range between 0.2 & 1.??
I think maybe there is something wrong....