Jump to content



Latest Downloads


Recent Status Updates

View All Updates

Chemical and Process Engineering Resources

- - - - -





Category: Chemistry Basics
Question: How can hexavalent chromium be removed from aqueous waste streams?
Keywords: hexavalent,trivalent,chromium,removal,precipitation,waste,ferrous,sulfate
Answer: One option is to use ferrous sulfate to reduce the hexavalent chromium to a less toxic, trivalent chromium form that will precipate out of the solution. Trivalent chromium can then be reduced by sodium hydroxide.