Category: Fluid Dynamics
Question: For mixing with a circulation pump, what's a good rule of thumb to determine when the tank will be "well mixed"?
Keywords: mixing,rule,thumb,well,circulation,pump,tank
Answer: A common used rule is:time = (3* volume)/circulation rate for mixing with a circulation tank.