Latest Downloads
-
Water Bath Indirect Heaters
Art Montemayor - Oct 12 2018 02:35 PM
-
Petroleum: A Primer for Kansas
Art Montemayor - Oct 12 2018 02:27 PM
-
Spray Tower for Flue Gas Scrubbing Design
ankur2061 - May 02 2018 02:31 PM
-
Selection of Vertical Tanks
ankur2061 - Apr 19 2018 07:42 AM
-
Pressure Drop Calculator for Strainers 1
ankur2061 - Mar 24 2017 02:04 PM
-
Horizontal Pig Trap System Design Guidelines
ankur2061 - Jan 14 2017 02:54 PM
-
Performance Prediction of 3-Stage Propane Refrigeration System
ankur2061 - Aug 08 2016 02:43 PM
-
Centrifugal Pump Troubleshooting Checklist
ankur2061 - Dec 17 2015 08:18 AM
-
Compressor Troubleshooting Checklist
ankur2061 - Sep 08 2015 11:43 AM
-
Amine Sweetening Unit Preliminary Design
ankur2061 - May 19 2015 09:35 AM
Popular Store Titles
Tank Jacket Calculator
Specification Sheet Collection
PIPESIZE
Relief Valve Sizing
Rupture Disc Sizing
Chemical and Process Engineering Resources
Submitted Chris Haslego, Nov 21 2011 11:21 AM | Last updated Nov 21 2011 01:29 PM
Category: | Industrial Utilities |
Question: | When specifying a cooling tower, should I look up historic wet bulb temperatures for my area or should I take measurements? |
Keywords: | cooling,tower,wet,bulb,temperature,entering,ambient |
Answer: | If this is a new installation, look up historical wet bulb temperatures for area and be sure to report them to the cooling tower manufacturer as "ambient wet bulb temperatures". The manufacturer will adjust this temperature accordingly to estimate an "entering wet bulb temperature". If you have an existing tower that is to be replaced, take several wet bulb temperature measurements near the air inlet during the hottest months. Report this as the "entering wet bulb temperature" to the tower manufacturer. The difference between the ambient and the entering wet bulb temperatures is to account for wet recirculation from the tower exit back to the tower entrance. The entering wet bulb temperature always higher than the ambient wet bulb temperature. |
Links: | Cooling Towers: Design and Operation Considerations |
Forum Quick Links
Tech Q & A Category List
-
Bulk Solids
-
ChE Outside the Plant
-
Chemical Process Business
-
Chemistry Basics
-
Corrosion
-
Equipment Design
-
Experimentation and Testing
-
Fluid Dynamics
-
Heat Transfer Technology
-
Industrial Utilities
-
Mass Transfer
-
Physical Property Information
-
Plant Basics
-
Plant Economics
-
Preparing to Become an Engineer
-
Process Control
-
Reactions and Processes
-
Refining
-
Safety
-
Separation Technology
-
The Environment
-
Thermodynamics
0 Comments